ODAD2 Human siRNA Oligo Duplex (Locus ID 55130)
CAT#: SR310511
ARMC4 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each
Need single siRNA in bulk?
Get a free quote
CNY 4090.00
货期*
7周
规格
Product images

推荐一起购买 (3)
Specifications
Product Data | |
Purity | HPLC purified |
Quality Control | Tested by ESI-MS |
Sequences | Available with shipment |
Stability | One year from date of shipment when stored at -20°C. |
# of transfections | Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM). |
Note | Single siRNA duplex (10nmol) can be ordered. |
Reference Data | |
RefSeq | NM_001290020, NM_001290021, NM_001312689, NM_018076 |
Synonyms | ARMC4; CILD23; gudu |
Components | ARMC4 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 55130)Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmolIncluded - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml |
Summary | The protein encoded by this gene contains ten Armadillo repeat motifs (ARMs) and one HEAT repeat, and is thought to be involved in ciliary and flagellar movement. This protein has been shown to localize to the ciliary axonemes and at the ciliary base of respiratory cells. Studies indicate that mutations in this gene cause partial outer dynein arm (ODA) defects in respiratory cilia. The cilia of cells with mutations in this gene displayed either reduced ciliary beat frequency and amplitude, or, complete immotility. Some individuals with primary ciliary dyskensia (PCD) have been shown to have mutations in this gene. PCD is characterized by chronic airway disease and left/right body asymmetry defects. Alternative splicing results in multiple transcript variants encoding different isoforms. [provided by RefSeq, Aug 2015] |
Performance Guranteed | OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency. For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required). |
Documents
Product Manuals |
FAQs |
SDS |
Customer
Reviews
Loading...